Installation Of the ELTECH Disk Anode
is a Simple And Quick Process

  1. Drill a 1-5/16" hole through the steel bulkhead. If a 1" hole is already in place, it will be necessary to ream the hole an additional 5/16".
  2. Apply silicone caulking to the entire back of the FRP shield being careful not to cover the EPDM seal. This servers to displace water on the steel surface, thereby minimizing corrosion of the bulkhead behind the shield. Enough caulking should be applied so that a small bead forms around the entire shield perimeter after the disk jam nuts are tightened.
  3. Once the disk is mounted, install and tighten the lock nuts against each other. It is suggested that the disk be attached at about 50% of its design torque - approximately 25 ft. lbs. On concave surfaces make sure the spacer gasket has been fitted before installing disk in a hole.
  4. Electrical connection to the titanium rod should be made with a zinc plated spade type wire terminal with a circular opening for a 1/4" rod. Make sure any exposed copper wire is appropriately protected with heat shrink, petrolatum tape or other suitable water barrier.
  5. For submersion service, it is advisable to fill the conduit box with a silicone or epoxy potting compound.
Headquarters
4411 Navigation Blvd.
Houston, TX 77011
800-454-9451
(713) 225.6661
(713) 225.5044 Fax
195 S. Fourth St.
Beaumont, TX 77701
(800) 640.7785
(409) 838.1641
Fax (409) 838.3623
7108 W. Hwy. 80
Midland, TX 79706
(800) 226.7788
(432) 561.5360
Fax (432) 561.5400
 
Home :: Cathodic Protection :: Power Transmission :: RFQ :: Contact Us
© 2007 Brance-Krachy Co Inc. All rights reserved. | Site Map