Charts And Graphs For Tubular Anode
Maximum Rated Current Output As A Function
Of Design Lifetime

Maximum Rated Current Output As A Function
Of Design Lifetime

Maximum Rated Current Output As A Function
Of Design Lifetime

Maximum Rated Current Output As A Function
Of Design Lifetime

ELTECH LIDA® Tubular Anodes Specification
| Application |
Anode Type |
Life |
Temp |
Max.
Rated
Output
(amps) |
Temp |
Max.
Rated
Output (amps) |
| Coke (Soil) |
FW/ST 2.5/100 |
20 |
|
11.0 |
|
|
| FW/ST 2.5/50 |
20 |
|
5.5 |
|
|
| FW/ST 2.5/152 |
20 |
|
16.9 |
|
|
| Fresh Water |
FW/ST 2.5/100 |
20 |
above 5° C
(40° F) |
13.5 |
below 5° C
(40° F) |
9.5 |
| FW/ST 2.5/50 |
20 |
6.8 |
4.8 |
| FW/ST 2.5/152 |
20 |
21.0 |
|
| Brackish Water |
FW/ST 2.5/100 |
15 |
above 5° C (40° F)
|
20 |
below 5° C (40° F)
|
14.0 |
| FW/ST 2.5/50 |
15 |
10 |
7.0 |
Mud
Fresh or
Brackish |
MT/ST 2.5/100 |
15 |
above 5° C (40° F)
|
11.2 |
below 5° C (40° F)
|
7.8 |
| MT/ST 2.5/50 |
15 |
5.6 |
3.9 |
| Seawater |
SWT 2.5/100
|
15 |
above 10° C (50° F)
|
37.5 |
below 10° C (50° F)
|
26.3 |
| SWT 2.5/50 |
15 |
19.0 |
13.3 |
| SWT 2.5/152 |
15 |
58.3 |
|
| Mud - Saline |
MT 2.5/100 |
15 |
above 10° C (50° F)
|
18.8 |
below 10° C (50° F)
|
13.2 |
| MT 2.5/50 |
15 |
9.5 |
6.7 |